RNA Sequencing Sample Requirements: Sample Input and Quality - Novogene
A successful RNA-seq submission starts with five checks: total amount, concentration, volume, integrity, and purity. Each measurement addresses a different requirement. Amount determines whether there is enough material to build a library; concentration and volume determine whether the sample can be processed; integrity indicates how much of the transcriptome remains intact; and purity helps identify contaminants that may interfere with downstream reactions.
There is no single minimum RNA input that applies to every RNA-seq project. Requirements vary by library type and sample type. Use the specifications below as a guide, and follow the project confirmation sheet if it provides different or more specific instructions.
RNA-seq Sample Requirements at a Glance
The table summarizes the minimum input and quality criteria provided in the supplied Novogene America sample submission guidance.
| Library Type | Sample | Minimum Amount | Minimum Concentration | Minimum Volume | RIN / Integrity |
| Eukaryotic mRNA (poly(A) enrichment) | Total RNA: animal, plant, or fungus | 100 ng | 10 ng/μL | 10 μL | ≥ 4.0; flat baseline |
| Eukaryotic mRNA (poly(A) enrichment) | Total RNA: blood | 400 ng | 20 ng/μL | 20 μL | ≥ 5.0; flat baseline |
| Strand-specific eukaryotic mRNA (poly(A) enrichment) | Total RNA: animal, plant, or fungus | 200 ng | 10 ng/μL | 20 μL | ≥ 5.0; flat baseline |
| Strand-specific eukaryotic mRNA (poly(A) enrichment) | Total RNA: blood | 400 ng | 20 ng/μL | 20 μL | ≥ 5.0; flat baseline |
| lncRNA (strand-specific; rRNA-depletion) | Total RNA: human, animal, plant, or fungus | 300 ng | 30 ng/μL | 10 μL | ≥ 5.5; flat baseline |
| lncRNA, ultra-low input | Total RNA: human, mouse, or rat | 25 ng | 1 ng/μL | 15 μL | ≥ 5.5; flat baseline |
| lncRNA | Total RNA: blood (human, mouse, or rat) | 120 ng | 10 ng/μL | 15 μL | ≥ 5.5; flat baseline |
| Prokaryotic RNA (rRNA-depleted) | Total RNA | 500 ng | 50 ng/μL | 10 μL | ≥ 6.0; flat baseline |
| Dual RNA (double rRNA depletion) | Total RNA | 1 μg | 50 ng/μL | 20 μL | ≥ 6.5; flat baseline |
| Metatranscriptome (double or triple rRNA depletion) | Total RNA | 1 μg | 50 ng/μL | 20 μL | ≥ 5.8; flat baseline |
Input amounts should be measured fluorometrically (Qubit), while purity should be assessed spectrophotometrically (NanoDrop). The same purity criteria apply across all library types listed above: A260/A280 ≥ 2.0 and A260/A230 ≥ 2.0. For strand-specific mRNA libraries, the minimum concentration is 10 ng/μL for tissue samples and 20 ng/μL for blood samples.
Why RNA Quality Is Evaluated Differently from DNA Quality
When RNA input falls below the recommended threshold, library complexity can decrease. The same sequencing depth may then cover fewer unique molecules, duplication can increase, and low-abundance transcripts may be missed. In poly(A)-enrichment workflows, low input can also reduce the effectiveness of rRNA removal by selection.
The RNA Integrity Number (RIN) is derived from the electropherogram profile. A clear 18S and 28S ribosomal RNA peak pattern generally indicates better integrity, while a broad or low-molecular-weight smear suggests degradation. RIN evaluates integrity, not purity: a sample can have a high RIN and still contain contaminants, or have a lower RIN while remaining chemically clean. For mRNA libraries, the supplied guidance specifies assessment using an Agilent 2100 Bioanalyzer.
Partially degraded RNA is not automatically unusable. rRNA-depleted library preparation can be more suitable than poly(A) selection for some degraded samples because it does not rely on an intact poly(A) tail. However, the applicable QC threshold still depends on the library type. In the supplied guidance, the RIN threshold is ≥ 5.5 for rRNA-depleted lncRNA libraries and ≥ 4.0 for standard poly(A) mRNA from tissue. For FFPE material, fragment-size distribution is used in place of RIN.
How RNA Quality Is Measured: Three Types of Assessment
| Measurement | Method | What It Indicates | When It Is Used |
|---|---|---|---|
| Concentration | Fluorometric assay (Qubit) | RNA amount measured using an RNA-selective dye-based assay. | Primary measurement for determining RNA input amount. |
| Concentration | Spectrophotometry (NanoDrop) | Absorbance at 260 nm; detects nucleic acids and other UV-absorbing substances. | Cross-checking concentration and screening for potential contamination. |
| Integrity | RIN using an Agilent 5400 Bioanalyzer (mRNA libraries) | RNA size-distribution profile compared with a reference. | When the selected library type has a RIN threshold. |
| Integrity | DV200 or fragment-size distribution | The proportion of RNA fragments above a defined size cutoff. | FFPE and degraded samples for which RIN is not the applicable metric. |
| Purity | A260/A280 | Can indicate protein carryover. | A value below 2.0 may indicate protein contamination; the supplied guideline threshold is ≥ 2.0. |
| Purity | A260/A230 | Can indicate carryover of polysaccharides, phenol, salts, or guanidine. | A value below 2.0 may indicate residual extraction reagents or other contaminants. |
Qubit and NanoDrop measurements can differ because they measure different properties. Fluorometric quantification is RNA-selective, while spectrophotometry measures absorbance from substances that absorb at 260 nm, including other nucleic acids and contaminants. A higher NanoDrop reading therefore does not necessarily mean that more usable RNA is available for library preparation. Use the fluorometric result to determine input amount and the spectrophotometric result as a purity cross-check.
Sample Types and Special Considerations
Whole blood often has a higher RNA input requirement than other common eukaryotic sample types, and the collection tube can affect sample suitability. When immediate extraction is not possible, an appropriate stabilization tube can help preserve the expression profile. Follow the tube manufacturer’s stated processing window and record the tube type on the Sample Information Form. Flash-frozen anticoagulated blood is another option; avoid heparin collection tubes because heparin can inhibit reverse transcriptase.
Plant RNA can be difficult to purify because polysaccharides and polyphenols may co-purify with RNA and inhibit downstream enzymes. Choosing an appropriate extraction method is therefore important. Formalin fixation progressively fragments RNA. Fresh FFPE blocks or unstained sections are generally preferable to aged or stained material, and sample acceptance is assessed using fragment-size distribution rather than RIN.
When Novogene Performs the RNA Extraction
If you are submitting tissue or cells rather than purified RNA, the starting-material requirements are different. The amounts below are project-level intake guidance. The Sample Submission Guidelines cited above cover purified RNA; confirm tissue and cell requirements against the current Sample Preparation Guide and your project confirmation sheet before shipping.
| Sample Type | Recommended Submission Amount | Notes |
|---|---|---|
| Fresh plant tissue (leaf or flower) | ≥ 0.3 g fresh weight | For roots, stems, and seeds, submit 0.5–1 g. Mature plant parts may benefit from approximately twice the standard amount. |
| Fresh animal tissue (visceral tissue or brain) | ≥ 0.08 g fresh weight | For fat, skin, bone, and vessel tissue, submit ≥ 0.3 g; more may be needed when nucleic acid content is low. |
| Fresh cultured cells | ≥ 5 × 10⁶ cells | At least 1 × 10⁶ cells are needed for one extraction; 5 × 10⁶ to 1 × 10⁷ cells is preferred. |
| Whole blood, lysed in TRIzol | ≥ 5 mL | Use a blood-to-TRIzol ratio of 1:3. Not recommended for small RNA or circRNA libraries. |
| Whole blood, flash-frozen | ≥ 2 mL | Use anticoagulated, heparin-free blood. |
| Blood in stabilization tubes | ≥ 1 tube | Preferred route for human and primate blood. |
| FFPE sections | 5–10 μm thick; section count specified in the project sheet | Fresh blocks or unstained sections are preferred. Avoid de-waxed, stained, or re-thawed material. |
| Bacterial pellet or mycelium | ≥ 3 × 10⁶ cells or ≥ 0.3 g | Increase the amount for low-yield species or submit enough material for three runs. |
Two handling principles apply across sample types. First, flash-freeze tissue within minutes of dissection and avoid thawing and refreezing. A thawed sample may no longer meet the required integrity criteria. Second, do not submit substantially more tissue than requested simply as a precaution: overloading an extraction can reduce lysis efficiency and compromise RNA quality.
Preparing and Shipping RNA Without Compromising Quality
Store purified RNA at −80 °C and ship it on dry ice. If a sample is preserved in a stabilization solution, ship it in that solution rather than drying it down. Use 1.5-mL microcentrifuge tubes; plates can increase the risk of cross-contamination. Freeze–thaw cycles are a common and avoidable cause of post-extraction RNA degradation, so prepare separate aliquots during purification whenever possible.
If samples will be used for multiple projects or omics applications, prepare separate tubes for each purpose and reserve RNA for the intended RNA-based analysis first. A repeat library preparation requires another full input amount for the relevant library type. Keep a backup aliquot in your own freezer when feasible.
RNA-seq Sample Submission Checklist
· Confirm that the total RNA amount, measured fluorometrically, meets the minimum requirement for the selected library type.
· Confirm that the RNA concentration meets the minimum and that the required input amount fits within the available volume.
· Confirm that the sample volume is within the specified range and that RIN meets the applicable threshold, with a flat baseline where specified.
· Check purity: A260/A280 ≥ 2.0 and A260/A230 ≥ 2.0. Review the sample for signs of degradation or contamination.
· Record the solvent and any stabilization solution on the Sample Information Form.
· Prepare aliquots during purification to minimize freeze–thaw cycles.
· Use 1.5-mL microcentrifuge tubes, label each tube to match the Sample Information Form, and retain a backup aliquot when possible.
· For tissue submissions, flash-freeze samples promptly after collection and avoid thawing and refreezing.
Frequently Asked Questions
The minimum depends on the library type. The supplied guidance lists 100 ng of total RNA for standard poly(A) mRNA from tissue, 400 ng for blood, 200 ng for strand-specific mRNA from tissue, 300 ng for rRNA-depleted lncRNA (with an ultra-low-input option at 25 ng), and 500 ng for prokaryotic RNA libraries. Other library types have different requirements; refer to the table above and confirm the requirements for your project.
What RIN value is acceptable for RNA-seq?The RIN threshold depends on the library type: ≥ 4.0 for standard poly(A) mRNA from tissue; ≥ 5.0 for blood and strand-specific mRNA; ≥ 5.5 for lncRNA; ≥ 5.8 for metatranscriptome; ≥ 6.0 for prokaryotic RNA; and ≥ 6.5 for dual RNA. A sample that meets the threshold for one library type may not meet the threshold for another. For exosomal lncRNA and FFPE samples, follow the applicable fragment-size criteria.
What if my RNA samples are degraded or are derived from FFPE material?An rRNA-depleted library may be more suitable than poly(A) selection for some degraded RNA because it does not depend on an intact poly(A) tail. For FFPE material, acceptance is assessed using fragment-size distribution rather than RIN. Fresh blocks or unstained sections are generally preferable to aged or stained material.
Should I use Qubit or NanoDrop values to assess RNA concentration?Use the fluorometric Qubit measurement to determine RNA input amount because it selectively measures RNA. Use NanoDrop as a cross-check for concentration and purity. A260/A280 can indicate protein carryover, while A260/A230 can indicate residual extraction reagents or other contaminants. NanoDrop readings may overestimate usable RNA when contaminants are present.
How much additional RNA should I prepare in case library preparation needs to be repeated?Prepare a separate aliquot containing one additional full input amount for each library type. If re-extraction is required, another full tissue or cell input amount will be needed. For tissue submissions, include a backup portion when possible.